Inara Crest Technologies — home
Cart, empty

Popular searches

GuideInfrastructure & networking

Labelling standard for a small office network

By Inara Crest Engineering 1 min read

A simple, consistent labelling scheme for outlets, patch panels, cables and devices that anyone can follow.

Good labels save hours during every fault and change. A scheme only needs to be simple and applied consistently.

1. Outlets

Label each outlet with floor, room and number, for example F1-R04-02. Use the same identifier at the patch panel.

2. Patch panels

Number panels within each rack (A, B, C) and ports sequentially.

3. Patch cords

Use colour to indicate function — for example blue for data, yellow for cameras, red for uplinks — and label both ends for critical links.

4. Devices

Label switches, routers and access points with their hostname, which matches the network documentation.

5. Records

Keep an outlet schedule mapping outlets, panel ports, switch ports and connected devices.

See our structured cabling services.

About the author

Inara Crest Engineering

Engineering team

Written by the Inara Crest Technologies engineering team, who design, install and support software, network, security, power and data centre systems for organisations in Kenya and East Africa.

All guides